§ 6. Wind energy conversion systems (WECS).  


Latest version.
  • Wind energy conversion systems (WECS) may be permitted subject to the following requirements:

    (1)

    The minimum distance from any lot line to any tower, pole or other support structure of the wind energy conversion system shall be established by the following minimum standards:

    Rotor diameter
    (feet)
    Setback
    Distance
    (feet)
     5 100
    10 165
    15 220
    20 270
    25 310
    30 340
    35 365
    40 385

     

    Intermediate rotor size distances shall be interpolated from the above values.

    (2)

    The WECS shall not be located in any required yard.

    (3)

    The WECS shall not cause interference to microwave communications or radio and television reception in the area. Noise levels measured at the lot line shall not exceed sixty (60) dBA in a residential zone.

    (4)

    To limit climbing access to WECS tower, or other support structure, a six (6) foot high fence with locking portal shall be placed around the WECS support or if a tower is utilized, the tower climbing apparatus shall be limited to lower than twelve (12) feet from the ground or the WECS support may be mounted on a roof top.

    (5)

    All blades of a WECS shall be constructed of nonmetallic substances. If the applicant can prove, in written form, that no electromagnetic interference will result, a metal content of up to twenty-five (25) per cent will be acceptable.

    (6)

    The WECS shall be located in compliance with the guidelines of the federal aviation regulations with regard to airport approach and clearance around VOR and DVOR stations.

    (7)

    Height of the WECS shall not exceed the maximum height restriction in the zone where it is located by more than twenty (20) feet. The height of the WECS shall be measured at the center of the blade diameter.

    (8)

    Data pertaining to the WECS's safety and structural integrity shall be certified by a licensed engineer and filed with the building permit application. The tower or support and top adaptor shall meet the restrictions specified in the city's building code.

    (9)

    The WECS, if interconnected to a utility system, shall meet the requirements for interconnection and operation as set forth in the electric utility's current service regulations applicable to WECS.

    (10)

    A plot plan shall be submitted with the application for building permit showing the proposed location and height of the WECS, fencing and all existing buildings within two hundred (200) feet of the exterior lot lines.

    (11)

    The owner/operator shall provide covenants, easements or similar documentation to assure sufficient wind to operate the WECS unless adequate accessibility to the wind is provided by the site.

    (12)

    The owner/operator shall certify that the WECS does not violate any covenants of record.

    (13)

    The applicant shall provide a certificate of liability insurance. Annually the owner/operator shall present evidence to the zoning administrator that the liability insurance is still in effect.

(Ord. No. 1574, § 1, 7-14-88; Ord. No. 1727, 6-13-96)